Platform Tests of milk
1A: COB Test :
Requirements (Instruments, Chemicals & Other) :
- Milk sample
- Test tubes
- Water bath
Procedure :
- Take 5ml of milk from each sample in a separate test tube.
- Place the test tubes in a boiling water bath for 5 minutes.
- Remove the tube from water bath without shaking.
- Observation is No clot formation- Negative and Clot formation-Positive
1B: MBRT Test :
Requirements (Instruments, Chemicals & Other) :
- Milk sample
- Standard methylene blue solution
- Test tubes
- Water bath
Procedure :
- Take 10 ml of milk from each sample and pour in a two separate test tube
- Add 1 ml of standard methylene blue solution in both the test tubes.
- Invert the test tube to mix the milk and methylene blue solution.
- Place the test tube in a thermostatically water bath maintained at 37°C.
- Observe the test tubes after 30 min for decolourization /reduction of dye.
- Place the test tubes again in the water bath for 2 hr if not decolorizes
- Observe the test tubes after 2 hr for decolourization /reduction of dye
- Repeat the procedure of incubation for 5 hr if not decolorizes